Re: NEC-LIST: RF Voltage Levels

From: Ben Dawson <dawson_at_email.domain.hidden>
Date: Sat, 29 Dec 2007 11:41:11 -0500

Roy Lewallen wrote:
> NEC can tell you the voltage stress on insulators. Include the guy
> wires in the model, representing the insulators with high impedance
> loads. Then find the voltage across each insulator by multiplying the
> magnitude of the load impedance times the magnitude of the current at
> the loaded segment. You'll have to increase the load impedances until
> the voltage doesn't change appreciably with changes in impedance.
>
> For corona, I think you'll have to find the magnitude of the E field
> near the points of interest using NE, as Paul Lynas suggested.
>
> Roy Lewallen
>
NecList:

Mr. Lewallen is entirely correct. We have used these methods for
decades to predict both insulator voltages and surface voltage gradients
for corona prevention on dozens of complex MF, LF and VLF antennas at
power levels up to 2 megawatts. A guy or station post insulator can be
modeled either as a high R (100 k is usually good enough) or as a small
capacitance.

Benj. F. Dawson III, P.E.
Hatfield & Dawson Consulting Engineers LLC
9500 Greenwood Avenue North
Seattle, WA 98103 USA

-- 
The NEC-List mailing list
NEC-List_at_robomod.net
http://www.robomod.net/mailman/listinfo/nec-list
Received on Sat Dec 29 2007 - 16:41:28 EST

This archive was generated by hypermail 2.2.0 : Sat Oct 02 2010 - 00:10:46 EDT